CVE-2026-24890

Severity:

HIGH RISK

(8.1)

Authorization Bypass in OpenEMR Patient Portal

CVE-2026-24890

Analyzed

Vulnerability type

Category:

Authorization Bypass

CWE:

CWE-285

Impact:

Privilege Escalation and Data Integrity Compromise

Severity:

HIGH RISK

(8.1)

CVSS version:

3.1

Catch this CVE while code is being written

Detect vulnerable code directly in pull requests, so CVEs are fixed before merge.

Summary

An authorization bypass in the OpenEMR patient portal signature endpoint allows authenticated portal users to upload or overwrite provider signatures by misusing the type=admin-signature parameter and specifying arbitrary provider user IDs.

When exploited, this can lead to forged provider signatures on medical documents, with potential legal, regulatory, and fraud implications in clinical workflows that rely on digital signatures as proof of provider approval.

Affected context

The vulnerability appears in OpenEMR deployments that expose the patient portal functionality and rely on its signature upload endpoint to manage both patient and provider signatures.

It becomes relevant when:

  • Portal users can authenticate and access signature-related features
  • The same endpoint or logic path is used for both patient and provider (admin) signatures
  • Signature updates are accepted based primarily on request parameters (e.g., type and provider user ID) rather than on strict permission checks tied to the caller's identity

In such environments, an otherwise low-privilege portal account can affect records that should be controlled only by provider or administrative accounts.

Exploit preconditions

  • Attack surface: HTTP(S) patient portal API / web endpoint responsible for handling signature uploads.
  • Required access: Any authenticated patient portal account; no elevated provider or admin role is required.
  • Trigger point: Submitting a crafted request to the signature endpoint that:
  • Sets type=admin-signature
  • Supplies an arbitrary provider user ID to target
  • Why exploitation is possible: The endpoint trusts client-supplied fields (type, provider ID) to decide which signature to modify, and does not enforce that the calling user is actually the provider or is authorized to manage provider signatures. This broken authorization check allows low-privilege users to perform actions reserved for higher-privilege roles.

Why this happens

The root cause maps to CWE-285: Improper Authorization.

The affected logic treats authorization as implied by:

  • Being authenticated to the portal, and
  • Supplying specific parameter values (type=admin-signature, chosen provider ID),

rather than explicitly verifying that the caller has the provider or administrative role linked to the targeted signature.

This is an insecure pattern where:

  • Role- or ownership-sensitive operations are gated only by easily manipulated request parameters.
  • The server does not re-derive authority from server-side session data or role assignments.

Conceptually, this is a broken object-level authorization (BOLA) style bug on a signature resource: users can operate on signature records that they do not own and are not entitled to modify.

Potential impact

  • Forgery of provider signatures on medical documents and records.
  • Corruption of clinical documentation integrity, including treatment plans, prescriptions, and encounter notes that rely on provider approval.
  • Legal and regulatory compliance issues (e.g., disputes over who approved or signed a document).
  • Facilitation of insurance or billing fraud by attaching falsified provider approvals to claims.
  • Erosion of auditability and trust in electronic health records, complicating incident response and forensic investigations.

General mitigation guidance

Mitigation typically focuses on strengthening authorization logic around sensitive resources like provider signatures:

  • Enforce role-based access control (RBAC): only users with provider or appropriate administrative roles should be permitted to upload or modify provider signatures.
  • Implement ownership and relationship checks: server-side code should verify that the session user is the provider whose signature is being modified or has an explicitly granted delegation.
  • Avoid relying on client-supplied fields (such as type or arbitrary user IDs) to determine authorization or resource ownership; derive these from server-side context and mappings.
  • Separate endpoints or code paths for patient vs. provider signatures to reduce the risk of role confusion and parameter-based escalation.
  • Apply the principle of least privilege so that patient portal accounts are limited to operations on their own data and cannot influence provider-level artifacts.
  • Add robust auditing and monitoring for signature changes, including who initiated the change and when, to support detection and accountability.

How teams detect issues like this

Detection efforts can focus on both code-level and runtime signals:

  • Static analysis and code review:
  • Identify endpoints that modify provider or administrative resources (like signatures) and verify they contain explicit role/ownership checks.
  • Flag patterns where authorization is inferred solely from request parameters (type, user_id, etc.) instead of session-based identity and roles.
  • Review controller and service methods handling uploads to ensure they do not allow arbitrary user IDs to be passed unchecked.
  • Policy enforcement:
  • Define security coding standards requiring explicit authorization checks for all state-changing operations on provider or admin resources.
  • Use automated policy tools or linters that search for parameter-based authorization decisions and missing access control annotations.
  • Runtime monitoring:
  • Log all signature upload and modification actions with the caller's identity, target provider ID, and outcome.
  • Alert on unusual patterns, such as patients modifying multiple providers' signatures or frequent changes to provider signatures from non-provider accounts.

Sources

SourceLink
github.comgithub.com/openemr/openemr/commit/a29c0f7ac0975429a85cd09a3ff12ee0dcdb4478
github.comgithub.com/openemr/openemr/security/advisories/GHSA-xc8x-mfh8-9xvh

Frequently asked

questions

Yes. Any user who can remotely access the patient portal and authenticate with valid credentials could potentially exploit the issue, as the attack is carried out via standard web requests to the signature endpoint.

No. The vulnerability can be triggered by regular authenticated portal users because the authorization logic does not properly restrict provider signature modifications to provider or admin roles.

The most robust fix is to enforce strict, server-side authorization checks for all signature operations, ensuring that only the appropriate provider or an explicitly authorized administrative role can upload or overwrite provider signatures. This includes ignoring client-supplied identifiers for authorization decisions and deriving permissions from trusted session data and role mappings.

To prevent similar issues, adopt a consistent access control model where:

  • Every state-changing action on sensitive resources requires an explicit authorization check.
  • Authorization decisions are based on server-side identity, roles, and ownership relationships, not on client-controlled parameters.
  • Security-focused code reviews and automated checks target endpoints that manipulate high-value objects (such as signatures, prescriptions, or billing records).
  • Development teams follow a least-privilege design mindset, especially for patient-facing portal features.
Find out what's already