CVE-2024-55022

Severity:

HIGH RISK

(8.8)

Command Injection in Weintek cMT-3072XH2 HMI Name Parameter

CVE-2024-55022

Analyzed

Vulnerability type

Category:

Command Injection

CWE:

CWE-94

Impact:

Authenticated Remote Code Execution on HMI Device

Severity:

HIGH RISK

(8.8)

CVSS version:

3.1

Catch this CVE while code is being written

Detect vulnerable code directly in pull requests, so CVEs are fixed before merge.

Summary

Weintek cMT-3072XH2 easyweb v2.1.53 (OS v20231011) contains an authenticated command injection vulnerability in the HMI Name parameter.

An authenticated attacker who can modify this parameter may be able to inject and execute arbitrary system commands on the underlying device, leading to full compromise of the HMI environment.

Affected context

This vulnerability affects deployments of Weintek cMT-3072XH2 where the easyweb interface is exposed to users who can log in and configure or edit the HMI Name.

The issue arises when user-provided values for this field are processed in a way that allows operating system commands to be constructed or interpreted based on that input.

Environments where the web interface is reachable from broader internal networks, shared operator stations, or poorly segmented OT networks are more exposed.

Exploit preconditions

  • Attack surface: Web management / configuration interface of the Weintek cMT-3072XH2 device.
  • Required access: Valid authenticated session with sufficient privileges to view or modify the HMI Name parameter.
  • User interaction: Typically none beyond the attacker submitting a crafted HMI Name value through the easyweb UI or related HTTP request.
  • Trigger point: Server-side processing of the HMI Name, typically during save/apply of configuration or when the name is later used by backend scripts or system calls.
  • Why exploitation is possible: The application uses the HMI Name value in a context where it influences command-line construction, script execution, or shell interpretation without adequate sanitization or separation between data and commands, enabling injected content to be executed by the OS.

Why this happens

The underlying issue aligns with CWE-94, where input that should be treated purely as data is instead allowed to influence executable code or command behavior.

In this case, the HMI Name parameter—intended to be a simple label—is incorporated into backend logic that ultimately reaches an execution context such as a system command, shell, or interpreter.

Because the value is not strictly validated, encoded, or constrained to a safe format, special characters and sequences can break out of the expected data context and be interpreted as part of an executable command.

This pattern represents a classic command injection flaw, where business logic trusts configuration parameters and fails to enforce robust separation between user-controlled strings and execution mechanisms on the embedded OS.

Potential impact

  • Execution of arbitrary system commands with the privileges of the HMI web application or underlying service.
  • Full compromise of the HMI device, including unauthorized configuration changes or sabotage of control logic.
  • Pivoting into adjacent OT or IT networks reachable from the device, depending on routing and firewall rules.
  • Disclosure or tampering of process data displayed or logged by the HMI.
  • Use of the device as a foothold for persistent malware or as part of a botnet within industrial environments.

General mitigation guidance

Effective mitigation focuses on eliminating the ability for user-controlled values like HMI Name to influence command or code execution paths.

Common defensive patterns include:

  • Treating all configuration fields as untrusted input and enforcing strict whitelisting of allowed characters and length, particularly for label-like parameters.
  • Avoiding direct concatenation of user input into shell commands, script parameters, or interpreter strings; instead, using APIs that pass arguments as structured data.
  • Introducing a validation layer that normalizes and rejects values that contain metacharacters, control operators, or other syntax meaningful to shells or interpreters.
  • Running the web interface and associated services with the least privileges necessary, so that even if a command is executed, its impact is constrained.
  • Restricting network exposure of the easyweb interface through segmentation, VPN access, and access control lists, reducing the number of users who can reach and authenticate to the device.

Embedding these patterns into the general design of HMI configuration handling reduces the risk of similar bugs recurring across other parameters.

How teams detect issues like this

Detection typically combines code-centric and environment-centric approaches:

  • Static analysis: Search server-side code for patterns where configuration fields (including HMI Name) are concatenated into system commands, shell invocations, or interpreter calls; flag uses of generic execution APIs that receive raw string input.
  • Code review: During manual review, pay special attention to any place where user-configurable labels or names are passed to scripts, external binaries, or OS utilities; verify that validation and safe APIs are used.
  • Runtime monitoring: Enable logging of unusual command invocations on the device where feasible, such as commands containing unexpected characters or parameters derived from configuration fields.
  • Policy enforcement: Incorporate secure coding guidelines for OT and embedded web interfaces, and enforce checks in CI pipelines to prevent the introduction of new command injection patterns.

When available, automated security testing tools or specialized SAST products can help identify injection sinks and unvalidated inputs in firmware or web management code.

Sources

SourceLink
gist.github.comgist.github.com/AenganZ/f86ed0da28825a1432ec697f484622de
plain-trick-71d.notion.siteplain-trick-71d.notion.site/weintek-cMT-3072XH2-14687a89c4c181eeb21ad61e0392f34b?pvs=4

Frequently asked

questions

Yes, if the easyweb interface is exposed over the network and an attacker can reach it and authenticate, they can potentially exploit the vulnerability remotely without physical access to the device.

Yes. The vulnerability is described as authenticated command injection, meaning the attacker must first obtain or possess valid credentials with permission to modify the HMI Name parameter.

The most robust pattern is to eliminate dynamic construction of commands from user input altogether: use parameterized or API-based execution mechanisms, strictly validate and sanitize all configuration fields, and ensure that user-controlled data never directly forms part of executable command strings.

Adopt a secure development lifecycle for OT/embedded web applications that includes clear guidelines against command concatenation, automated checks for injection sinks, strict input validation for all configuration parameters, and regular security testing of device web interfaces before deployment.

Find out what's already